Fast temperature measuring with »E-FAqS«

Fast pyrometer »E-FAqS«
© Fraunhofer IWS
Fast pyrometer »E-FAqS«
Head of the pyrometers »E-FAqS«
© Fraunhofer IWS
Head of the pyrometers »E-FAqS«

Among the systems of Fraunhofer IWS the fast pyrometric system »E-FAqS« has been developed to get temperature information about very fast processes. This system is able to measure low temperatures from 160 °C and above with a sample rate lower than 30 μs. Since »E-MAqS« has been used for laser hardening and laser cladding so far, the much faster »E-FAqS« is applied more and more for laser soldering machines. »E-FAqS« is typically used in combination with the »LompocPro« control.


Application

  • controlled laser soldering, laser hardening, laser annealing, and plastics welding


Specifications

  • 19“-insert-PC with integrated optical sensor
  • optics connected to optical fibre with SMD-connector
  • measuring spot size adaptable
  • sensitive at 1.2 – 1.7 μm
  • sampling rate down to 50 μs
  • low noise signal transmitting over long distances
  • temperature ranges from 160 °C adaptable to applications